BQDCF - SKC-NF CLEANER/REMOVER
- MSDS: BQDCF
- Manufacturer: MAGNAFLUX
- Product Name: SKC-NF CLEANER/REMOVER
- National Stock Number: 6850-01-316-9422
Product Identification
Product ID:SKC-NF CLEANER/REMOVER
MSDS Date:01/01/1991
FSC:6850
NIIN:01-316-9422
MSDS Number: BQDCF
Responsible Party
CHICAGO, IL 60656
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 708-867-8000
Preparer: BRUCE C GRAHAM
Cage: 59042
Contractor
Telephone: 708-867-8000
Cage: 59042
Ingredients
METHYL CHLOROFORM (1,1,1-TRICHLOROETHANE)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 96%
OSHA PEL 350 PPM; 450 STEL
ACGIH TLV: 350 PPM; 450 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
CARBON DIOXIDE
CAS: 124-38-9
RTECS: FF6400000
Fraction By Weight: 5%
OSHA PEL 5000 PPM
ACGIH TLV: 5000PPM/30000STEL;93
METHANE, DIMETHOXY-; (METHYLAL)
CAS: 109-87-5
RTECS: PA8750000
Fraction By Weight: 1%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM
TERT-BUTYL ALCOHOL
CAS: 75-65-0
RTECS: EO1925000
Fraction By Weight: 1%
OSHA PEL 100 PPM
ACGIH TLV: 100PPM 9394
OF REGIONAL POISON CONTROL CENTER TO ASSIST MD.
RTECS: 9999999ZZ
BREATHE VAP. EXPOS ABOVE THE TLV CAN RSLT IN
RTECS: 9999999ZZ
& THOSE AROUND HIM/HER. MUCH LIKE INGESTING TOO MUCH
RTECS: 9999999ZZ
EITHER SUFFOCATION (LACK OF O*2), OR CARD ARREST.
RTECS: 9999999ZZ
MAY INCLUDE HCL & PHOSGENE .
RTECS: 9999999ZZ
SUCH AS THE INSIDE OF TANKS OR SMALL
RTECS: 9999999ZZ
MASK W/SEPARATE AIR SUPPLY.
RTECS: 9999999ZZ
AN EXHAUST VENT. REMEMBER THAT THE VAPS TEND TO SETTLE
RTECS: 9999999ZZ
THE CONC BELOW 350 PPM. ALMOST ALL OF THE SKC-NF
RTECS: 9999999ZZ
VENTILATION RATE ON CONSUMPTION.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:DIZZINESS, DROWSINESS & NAUSEA.
UNCONSCIOUSNESS AT HIGH EXPOSURE. SKIN:IRRITATES BY DISSOLVING SKIN
OILS. NOT ABSORBED THROUGH SKIN IN SIGNIFICANT AMOUNTS.
EYE:IRRITATING DUE TO STRONG SOLVENT A CTION. INGEST:LOW SINGLE
DOSE TOXICITY IN TEST ANIMALS. CHLOROCARBON MATLS HAVE PRDCED
SENSIT OF (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:THE MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS & COULD HAVE A SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G.
EPINEPHRINE) MAY BY CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES
IN HUMANS ACUTELY O R CHRONICALLY EXPOSED TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:NONE.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR. IF NOT BRTHG, CALL EMER VEHICLE
IMMED. GIVE MOUTH-TO-MOUTH RESUSCITATION. IF BRTHG IS DFCLT, GIVE
O*2. SKIN:WASH OFF IN FLOWING WATER/SHOWER. REMOVE CONTAMD CLOTHES
& WASH B EFORE REUSE. USE SOOTHING LOTION. EYE:LIFT UPPER & DEPRESS
LOWER EYELIDS & FLUSH W/A STEADY GENTLE FLOW OF WATER FOR AT LEAST
15 MINS. ROLL EYEBALL IN ALL DIRECTION WHILE FLUSHING. (SUPP DATA)
Fire Fighting
Flash Point:NONE
Lower Limits:SUPP DATA
Upper Limits:SUPP DATA
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:AEROSOL CANS MAY BURST AT TEMPS >130F.
VAPS PARTIALLY DECOMPOSE TO TOX GASES WHEN EXPOSED TO FLAME, ARCS
OR RED HOT SURF. THERMAL DECOMP PRODS (INGRED 9)
Accidental Release
Spill Release Procedures:LESS THAN 1 QT:WIPE UP, FOLLOWING GUIDELINES.
1 QT OR MORE:EVACUATE AREA. ENSURE THAT CLEAN UP CREW WEARS ALL
PERSONAL SAFETY WEAR AS PRESENTED. THE NOSE IS NOT A RELIABLE GAUGE
OF AIR CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE AWAY FROM HEAT SOURCES TO
MINIMIZE THE DANGER FROM EXPOS TO FIRES. STORE PALLETS OF AEROSOL
CARTONS AS LEVEL 1 AEROSOL (NFPA 30B).
Other Precautions:DO NOT HEAT AEROSOL CANS >130F TO ELIM THE POSS OF
THEIR BURSTING & RELEASING UNWANTED VAPS. DO NOT USE AROUND FLAME,
ARCS, RED HOT SURF OR LIGHTED SMOKING MATLS, SO AS TO AVOID EXPOS
TO PHOSGENE & HY DROCHLORIC ACID. DO NOT (INGRED 6)
Exposure Controls
Respiratory Protection:IN POORLY VENTD AREAS SUCH AS SMALL ROOMS W/NO
WINDOWS OR IN SUMPS OR OTHER LOW AREAS (SKC-NF VAPS ARE DENSE &
SINK TO LOW SPOTS) THE USER SHOULD WEAR A NIOSH/MSHA APPRVD RESP
W/CHEM CARTRIDGE. IN CON FINED, UNVENTD SPACES, (INGRED 10)
Ventilation:SKC-NF VAPS CANNOT BE ALLOWED TO COLLECT. IT IS PREFERRED
TO USE SKC-NF EITHER IN A SPRAY BOOTH/NEXT TO (INGRED 12)
Protective Gloves:NITRILE RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PROD:ODOR. HYDROCHLORIC ACID IS ALMOST AS TOX, TLV 5 PPM &
IS DETECTABLE & EVEN IRRITATING AT THIS CONC. FIRST AID
PROC:INGEST:DO NOT INDUCE VOM; IF VOM IS INHALED, IT MAY CAUSE
ASPHY. CONT MD IMMED. IMPORTANT:IN ALL SEV CASES, CONT MD IMMED.
LOCAL TELEPHONE OPERATORS ARE ABLE TO FURNISH NUMBER (INGRED 5)
Chemical Properties
Boiling Pt:B.P. Text:162F,72C
Vapor Pres:230 @ 100F
Vapor Density:4
pH:NEUT
Evaporation Rate & Reference:3X FASTER/ETHYL ALCOHOL
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR, COLORLESS, MOBILE LIQ; DETECTABLE ODOR AT
100 PPM.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
POWDERED ZINC & ALUMINUM.
Stability Condition to Avoid:PARTIALLY DECOMPOSES IN FLAME, ARCS OR
NEAR RED HOT SURFACES.
Hazardous Decomposition Products:PHOSGENE & HYDROCHLORIC ACID. PHOSGENE
IS EXTREMELY TOX, TLV 0.1 PPM & CANNOT BE RELIABLY DETECTED BY
(SUPP DATA)
Disposal
Waste Disposal Methods:DISPOSE OF AS EPA HAZARDOUS WASTE #F002. MAY BE
SENT TO SOLVENT RECLAIMER. ENSURE THAT AEROSOL CANS ARE EMPTY &
DEPRESSURIZED BEFORE DISCARDING, UNLESS A WASTE TREATMENT FACILITY
IS APPROVED TO ACCEPT THEM AS IS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.